We provide one-on-one training, method development, proposal writing, troubleshooting, and data analysis services to help you meet your biofilm-related analytical needs.

Our staff are highly trained and specialized experts with Ph.D.'s in biofilm science. Our Bioimaging and Analytical Core labs are equipped with state-of-the-art technologies and methods to provide you with the best results from your biofilm or other complex samples.

 

  • 96-well blocks incorporate VeriFlex technology for precise temperature control
  • Blocks are divided into isolated zones that allow separate cycling conditions within the same run — perfect for optimization
  • 6 optical channels and 21 filter combinations

QuantStudio 7 Pro

  • Sequential analysis of cations and anions in one sample
  • Capability to measure transition metals or lanthanides (Rare Earth Elements)
  • Small sample volume
  • High sensitivity to tens of ppb

Dionex ICS

  • Measures non-purgeable organic carbon and total nitrogen simultaneously
  • Dissolved inorganic carbon analysis
  • Sensitivity to ~4 ug/L C or N

Shimadzu TOC-L CPH

  • Highly sensitive fluorescence detector can detect four wavelengths simultaneously
  • Autosampler is temperature controlled and capable of complex pre-column derivitization reactions
  • Amino acid analysis and other fluorescent analytes

Dionex HPLC Ultimate

  • Two inline detectors variable wavelength and refractive index
  • Typical analyses include organic acids, sugars and alcohols
  • Modular to accommodate other columns or mobile phases
  • Quaternary pump for gradient methods

Dionex HPLC Ulyimate 3000 w VWD/RID

  • Electrochemical detector
  • AERS suppressor for low background
  • AS22 analytical column for separation on anions
  • 50 place autosampler
  • Detection limits from <1 mg/L to ~100 mg/L for common anions

Dionex Anion Ion Chromatography ICS 1100

  • Non-purgeable Organic Carbon (NPOC) measurements for Total Organic Carbon
  • Dissolved Inorganic Carbon (DIC)
  • IR detector of CO at 0.1 – 5000 mg C/l range of detection
  • 100 place autosampler

Skalar FormacsHT

  • Dual detectors inline- Thermal Conductivity Detector (TCD) and Flame Ionization Detector (FID) with Methanizer
  • Atmospheric detection of methane and other permanent gases
  • Methanizer allows for detection of CO and CO2 on FID
  • Nitrogen fixation via acetylene reduction to ethylene

Gas Chromatography SRI Instruments

  • Thermal Conductivity Detector (TCD)
  • Detection of methane and other permanent gases at levels produced by cultures
  • Manual injection of 0.5-1 mL

Gas Chromatography SRI Instruments with TCD